How radon mitigation systems work

Last updated

Sub-slab depressurization and other radon reduction methods explained, what installation involves, and how to check a system is working.

If your home tests at or above 4 pCi/L, EPA recommends fixing it. The good news, in EPA’s words: radon reduction systems work, some can cut radon levels by up to 99 percent, and most homes can be fixed for about the same cost as other common home repairs.

The main method: sub-slab depressurization

Most systems in homes with basements or slab foundations use active soil depressurization, often called sub-slab depressurization. A contractor:

  1. drills a hole through the floor slab and removes a small pit of fill beneath it,
  2. seals a plastic pipe into the hole,
  3. runs the pipe to a quiet in-line fan, usually in an attic, garage, or outside the house,
  4. vents the exhaust above the roof line.

The fan creates a gentle vacuum under the slab, so soil gas is pulled into the pipe and exhausted outdoors instead of seeping into the house. EPA explains that the discharge must go above the roof, away from windows and other openings, so the concentrated radon disperses and does not re-enter the home.

Other foundation types

  • Crawl spaces. A heavy plastic sheet (vapor barrier) is laid over the soil and sealed, and a pipe and fan draw air from beneath it. This is called sub-membrane depressurization.
  • Block walls. Hollow concrete block foundation walls may need their cavities depressurized too.
  • Sump pits. An existing sump can serve as the suction point if it is sealed with an airtight lid.

Supporting steps

Sealing cracks and openings in the foundation helps a system work better and saves energy, but EPA’s guidance is that sealing alone has not been shown to lower radon reliably. Ventilation approaches, such as heat recovery ventilators, can help in some homes.

Choosing a contractor

EPA recommends using a qualified mitigation contractor. It notes that states receiving federal indoor radon grants keep lists of providers credentialed through a state license or a national proficiency program (NRPP or NRSB). Get more than one estimate. Ask how the contractor will test the soil’s suction (“communication”) under the slab, where the pipe and fan will go, and whether a post-mitigation test is included. Your state radon program, linked on our state pages, can help.

Cost

EPA does not publish a national price. It says costs vary with the size and design of the home and the methods needed, and that most homes can be fixed for about the same cost as other common home repairs. The fan also uses some electricity continuously, and it will eventually need replacing.

Checking that it works

EPA’s guidance for owners:

  • Look at the warning device regularly. EPA says radon reduction systems need occasional maintenance and that you should check the system’s warning device on a regular basis. Many systems use a U-tube manometer on the pipe; uneven liquid levels show the fan is pulling a vacuum, and levels that even out suggest the fan has stopped.
  • Expect to replace the fan eventually. EPA notes fans may last five years or more (warranties tend not to exceed five years) and then need repair or replacement.
  • Retest. Test after installation to confirm the system worked, and retest periodically and after major renovations, as EPA’s testing guidance suggests.

If you are building new

Radon-resistant features are cheaper to install during construction. See radon-resistant new construction.

Sources

  1. U.S. EPA, How much can a radon mitigation system cost?
  2. U.S. EPA, How do I know if my radon mitigation system is working properly?
  3. U.S. EPA, Why must radon be vented into the air above my home’s roof?
  4. U.S. EPA, A Consumer’s Guide to Radon Reduction, via EPA radon publications