Living with a radon mitigation system: the manometer, the fan and retesting
Last updated
How to read the U-tube manometer, what to do if it reads zero, how long radon fans last, when to retest, and how remodeling or selling affects your system.
A radon mitigation system ranks among the simplest systems in any house: a pipe, a fan and a gauge. After it's installed and the follow-up test shows it works, it asks very little of you. "Very little" isn't nothing. EPA likens radon systems to a furnace or chimney, in that they need occasional maintenance. Below is what to check, what the readings mean, and when to test again.
What you have
Most homes with a basement or slab foundation end up with an active subslab depressurization system. A pipe passes through the floor slab (or into a sump or drain tile), runs up through the house or along the outside wall, and ends above the roofline. An in-line fan in the pipe, sitting in an attic, garage or outdoors, draws soil gas from under the house and sends it high into the air, where it thins out quickly. Crawlspace homes usually have a sealed plastic membrane over the dirt floor, connected to the same kind of pipe and fan. Our guide to radon mitigation systems goes through the designs.
EPA's installation standards call for several features you can see for yourself:
- a warning device that lets you know if the system stops working, placed where it can easily be seen or heard;
- a label on the system, so nobody changes it by accident;
- an exhaust that vents above the roof and at least 10 feet above the ground, and away from windows and doors;
- a fan that is not located in or below living space.
The manometer: your system's dashboard
EPA lists several kinds of warning devices: a liquid gauge, a sound alarm, a light indicator, or a dial gauge. The most common is a U-tube manometer, a small clear tube bent into a U, mounted on the vent pipe and partly filled with colored liquid.
How to read it
One side of the U connects to the inside of the pipe. While the fan runs, it creates suction in the pipe, which pulls the liquid up on one side and down on the other. The difference in height between the two columns tells you how much suction the fan is producing.
- Levels uneven (a gap between the two sides): the fan is pulling suction, and the system is running.
- Levels even (both sides at the same height, often reading "0"): there's no suction. The fan has stopped or lost power, or the pipe is disconnected or blocked.
Many installers mark the reading on installation day, or write it on the label. Small shifts across the seasons are normal, since soil moisture, frost and snow cover all affect airflow under the house. A big change from the installation reading is worth a phone call.
How often to look
EPA says to look at the warning device "on a regular basis." A practical habit is to glance at it once a month, or whenever you change your furnace filter or test your smoke alarms, and again after any power outage or electrical work.
If it reads zero
- Check whether the fan is running. You can usually hear or feel a faint vibration at the fan, or hear air moving at the pipe.
- Check the breaker and any switch or outlet the fan plugs into. Fans are often on their own circuit, and a switch flipped by accident is a common culprit.
- Look for a pipe joint that has come apart, especially after work in the basement or attic.
- If the fan has power and still won't run, it probably needs replacing. Call the installer, particularly if it's still under warranty.
If you have an alarm rather than a gauge, test it the way the installer showed you, and swap out its battery if it has one.
The fan
Never turn it off. EPA is firm on this: the fan should never be turned off, and it has to run continuously for the system to work. Once the fan stops, radon levels can climb back toward their old level.
Expect to replace it eventually. EPA says fans may last five years or more, and manufacturer warranties tend not to go past five years. Many fans last far longer, but plan on a replacement at some point. The cost of replacement depends on labor and materials, so EPA suggests getting estimates from qualified mitigators before any work begins.
Electric cost. Systems with fans work better, but they raise your electric bill slightly, and most systems lose some heated or cooled air. If your bill went up noticeably after installation, ask the contractor about the fan size and the sealing.
Noise or vibration. A new rattle, hum or whistle can point to a failing bearing or a loose mount. A service call is worth it before the fan quits.
Retesting
A system that worked on the first day can lose effectiveness over time. Foundations settle, a sump lid gets left off, or a fan weakens. EPA's guidance is:
- After installation: test within 30 days of installation, but no sooner than 24 hours after the system starts running with the fan on. Use a 2- to 7-day test, with windows and doors closed for 12 hours before and during the test, apart from normal entry and exit. EPA recommends an independent test, either by a separate tester or with a kit you place yourself.
- Every two years: EPA says it's a good idea to retest your home at least every two years to make sure radon levels stay low.
- After remodeling: retest in the lowest lived-in area once you remodel, to confirm the construction didn't reduce the system's effectiveness.
- If you start using a lower level: if you finish a basement or begin sleeping downstairs, test there.
Our guide to short-term vs. long-term radon tests explains which test to choose, and the radon level calculator compares your result with EPA's action level.
Remodeling and additions
Construction is a common way a working system gets broken. Before you remodel:
- Tell your contractor where the system is. Pipes get rerouted, new walls cover up the manometer, and fresh floor penetrations break the seal on the slab.
- Ask whether changes could void the warranty. EPA suggests talking this over with your radon contractor before the work starts.
- Plan for additions. If you're adding a new foundation, EPA says to ask your radon contractor what steps should be taken to keep radon low throughout the home, such as extending the suction system or roughing in a separate pipe.
- Keep the manometer visible. If it ends up boxed in, have it moved somewhere you can see it.
- Retest when the work is done.
Other equipment
Some homes use a heat recovery ventilator (HRV) as part of radon control. EPA says the HRV filter needs periodic cleaning and should be changed twice a year, and the outdoor fresh-air vent should be inspected for leaves and debris. The ventilator itself should be checked once a year.
Crawlspace membranes can tear when someone works under the house. After any work in the crawlspace, check that the plastic is still whole and still sealed along its edges and seams.
When you sell
A working, documented system is a selling point. EPA's Home Buyer's and Seller's Guide to Radon explains how radon is handled in a sale. Have these on hand:
- the original contract, system description and warranty;
- the test results from before and after mitigation;
- any later retest results and fan replacements;
- written operating and maintenance instructions.
A buyer's inspector will probably run a new test, so make sure the fan is running and the manometer shows suction before the house is listed. Our guide to radon when buying or selling a home covers testing during a sale.
Monthly and yearly checklist
Monthly
- Look at the manometer or alarm. If the liquid is uneven, it's working.
Yearly
- Listen to the fan for any new noise.
- Make sure the exhaust is clear (no bird nests or ice built up at the top) and the pipe joints are sealed.
- Check the crawlspace membrane and the seal on the sump lid, if you have them.
Every two years
- Retest with a short-term test in the lowest lived-in level.
After remodeling, a fan replacement, or a big change in the manometer
- Retest.
If you haven't tested yet, or you want to know your county's radon zone, begin with the ZIP lookup and then test. Every home should be tested, whatever its zone.
Free checklist · PDF
Radon Test Checklist
A one-page, step-by-step checklist for running a home radon test right the first time, and what to do with the number.
- Short-term vs. long-term test: which to use
- Closed-house conditions and where to place the kit
- What 2, 4 and 8 pCi/L mean and when to fix
Free. We email you the download link, plus an occasional plain-English guide. Unsubscribe any time. We never sell your email. Privacy
Sources
- U.S. EPA, Consumer's Guide to Radon Reduction: How to Fix Your Home
- U.S. EPA, How often should I test/retest my home for radon?
- U.S. EPA, Why must radon be vented to the air above my home's roof?
- U.S. EPA, Publications about radon (Home Buyer's and Seller's Guide to Radon)
- U.S. EPA, Consumer's Guide to Radon Reduction (2016)